G- constant torque load P- special for fans and pums 30kW/60A Heavy Duty-150% Overload/1 min; 37kW/75A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
4kW/9,5A Able to run at 110% of rated current for 1min, and an overload allowed for every 5min 3 Phase Input,3 Phase Output, 380-480 Volts 0-400 Hz GD270: Goodrive270 series VFD for fan and pump Space voltage vector control, and sensorless...
G- constant torque load P- special for fans and pums 37kW/75A Heavy Duty-150% Overload/1 min; 45kW/92A Normal Duty-110% Overload/1 min; G- constant torque load P- special for fans and pums 30kW/60A Heavy Duty-150% Overload/1 min; 37kW/75A...
22kW/45A Able to run at 110% of rated current for 1min, and an overload allowed for every 5min 3 Phase Input,3 Phase Output, 380-480 Volts 0-400 Hz GD270: Goodrive270 series VFD for fan and pump Space voltage vector control, and sensorless...
G- constant torque load P- special for fans and pums 4kW/9,5A Heavy Duty-150% Overload/1 min; 5,5kW/14A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
30kW/60A Able to run at 110% of rated current for 1min, and an overload allowed for every 5min 3 Phase Input,3 Phase Output, 380-480 Volts 0-400 Hz GD270: Goodrive270 series VFD for fan and pump Space voltage vector control, and sensorless...
G- constant torque load P- special for fans and pums 5,5kW/14A Heavy Duty-150% Overload/1 min; 7,5kW/18,5A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
1,5kW/4,0A Able to run at 110% of rated current for 1min, and an overload allowed for every 5min 3 Phase Input,3 Phase Output, 380-480 Volts 0-400 Hz GD270: Goodrive270 series VFD for fan and pump Space voltage vector control, and sensorless...
G- constant torque load P- special for fans and pums 7,5kW/18,5A Heavy Duty-150% Overload/1 min; 11kW/25A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
2,2kW/5,5A Able to run at 110% of rated current for 1min, and an overload allowed for every 5min 3 Phase Input,3 Phase Output, 380-480 Volts 0-400 Hz GD270: Goodrive270 series VFD for fan and pump Space voltage vector control, and sensorless...
G- constant torque load P- special for fans and pums 11kW/25A Heavy Duty-150% Overload/1 min; 15kW/32A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
5,5kW/12A Able to run at 110% of rated current for 1min, and an overload allowed for every 5min 3 Phase Input,3 Phase Output, 380-480 Volts 0-400 Hz GD270: Goodrive270 series VFD for fan and pump Space voltage vector control, and sensorless...
G- constant torque load P- special for fans and pums 15kW/32A Heavy Duty-150% Overload/1 min; 18,5kW/38A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
7,5kW/16A Able to run at 110% of rated current for 1min, and an overload allowed for every 5min 3 Phase Input,3 Phase Output, 380-480 Volts 0-400 Hz GD270: Goodrive270 series VFD for fan and pump Space voltage vector control, and sensorless...
G- constant torque load P- special for fans and pums 22kW/45A Heavy Duty-150% Overload/1 min; 30kW/64A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
11kW/24A Able to run at 110% of rated current for 1min, and an overload allowed for every 5min 3 Phase Input,3 Phase Output, 380-480 Volts 0-400 Hz GD270: Goodrive270 series VFD for fan and pump Space voltage vector control, and sensorless...
G- constant torque load P- special for fans and pums 18,5kW/38A Heavy Duty-150% Overload/1 min; 22kW/45A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
15kW/31A Able to run at 110% of rated current for 1min, and an overload allowed for every 5min 3 Phase Input,3 Phase Output, 380-480 Volts 0-400 Hz GD270: Goodrive270 series VFD for fan and pump Space voltage vector control, and sensorless...
This website uses cookies to provide a better user experience, analytics, advertising, and additional features. By selecting the option ‘I agree’, you allow the use of cookies for all the stated purposes. To adjust cookie permissions, click ‘Customize’. You can find more information about cookies
here.
These cookies are essential for the basic functioning of the website and are set in response to actions performed by the user, such as logging in, submitting forms, making purchases, and other interactions with website elements that go beyond simple passive browsing. These cookies are exempt from the requirement to obtain user consent.
Analytics cookies
Analytical cookies help us understand how users interact with the website, which enables us to improve the user experience. Data processing through these cookies is carried out on the basis of your explicit consent, which you can withdraw at any time.
Advertising cookies
These cookies are used to display personalized ads that are more relevant to you and your interests. They are also used to limit the number of times an ad is shown and to measure the effectiveness of advertising campaigns.
Social media cookies
These cookies enable the integration of social networks on our website, which includes sharing content or using social media features. The use of these cookies requires your consent, which we may obtain during your visit.