11 kW 23 A Heavy Duty-150% Overload/1 min Input: 380 ... 480 VAC ±10 % Three Phase Output: 380 ... 480 VAC ±10 % Three Phase V/f, sensorless vector control, torque control LED Keypad EMC FILTER-C3 50 °C operating temperature braking unit IP20,...
G- constant torque load P- special for fans and pums 185kW/340A Heavy Duty-150% Overload/1 min; 200kW/380A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 200kW/380A Heavy Duty-150% Overload/1 min; 220kW/425A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 220kW/425A Heavy Duty-150% Overload/1 min; 250kW/480A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 250kW/480A Heavy Duty-150% Overload/1 min; 280kW/530A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 90kW/180A Heavy Duty-150% Overload/1 min; 110kW/215A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 110kW/215A Heavy Duty-150% Overload/1 min; 132kW/260A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 280kW/530A Heavy Duty-150% Overload/1 min; 315kW/600A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 315kW/600A Heavy Duty-150% Overload/1 min; 355kW/650A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 355kW/650A Heavy Duty-150% Overload/1 min; 400kW/720A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 450kW/820A Heavy Duty-150% Overload/1 min; 500kW/860A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 4kW/9,5A Heavy Duty-150% Overload/1 min; 5,5kW/12,5 Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 1,5kW/3,7A Heavy Duty-150% Overload/1 min; 2,2kW/5,0A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 132kW/260A Heavy Duty-150% Overload/1 min; 160kW/305A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
G- constant torque load P- special for fans and pums 30kW/60A Heavy Duty-150% Overload/1 min; 37kW/75A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
This website uses cookies to provide a better user experience, analytics, advertising, and additional features. By selecting the option ‘I agree’, you allow the use of cookies for all the stated purposes. To adjust cookie permissions, click ‘Customize’. You can find more information about cookies
here.
These cookies are essential for the basic functioning of the website and are set in response to actions performed by the user, such as logging in, submitting forms, making purchases, and other interactions with website elements that go beyond simple passive browsing. These cookies are exempt from the requirement to obtain user consent.
Analytics cookies
Analytical cookies help us understand how users interact with the website, which enables us to improve the user experience. Data processing through these cookies is carried out on the basis of your explicit consent, which you can withdraw at any time.
Advertising cookies
These cookies are used to display personalized ads that are more relevant to you and your interests. They are also used to limit the number of times an ad is shown and to measure the effectiveness of advertising campaigns.
Social media cookies
These cookies enable the integration of social networks on our website, which includes sharing content or using social media features. The use of these cookies requires your consent, which we may obtain during your visit.