Description: AC Current Transducer to DC current (4..20 mA - loop powered) Power supply: on the output loop 4..20 mA Input: 8 selectable scales via DIP-SWITCH from ± 5 A to 40 A (AC) Accuracy: better than 0,2% Self-consumption: Answer Speed:...
Power Supply: 85 - 265 V AC with auxiliary power Display: Backlighted LCD 43x29 mm Harmonics: Yes (up to 15th) Recordings: MIN/AVG/MAX values for all powers Memory for data logs: 8 MB Accuracy class: 0,2% (voltage), 0,4% (current), 0,5% (power)...
Application: designed for measuring of temperature, differential pressure of natural gas and air Display: LCD, 19 digits, 2 lines, 75 x 40 mm, height 10 mm Measuring range: -100 ÷ 100 Pa Accuracy: ±0.5% (±2Pa) Persmissable overpressure: 21000Pa...
Application: designed for measuring of temperature, differential pressure of natural gas and air Display: LCD, 19 digits, 2 lines, 75 x 40 mm, height 10 mm Measuring range: -1000 ÷ 1000 Pa Accuracy: ±0.5% (±2Pa) Persmissable overpressure:...
Application: designed for measuring of temperature, differential pressure of natural gas and air Display: LCD, 19 digits, 2 lines, 75 x 40 mm, height 10 mm Measuring range: -10000 ÷ 10000 Pa Accuracy: ±0.5% (±10Pa) Persmissable overpressure:...
CO2 Measuring transducer: - Infrared measuring element - Duct mounting - Measuring range: 0 to 5000 ppm - 0-10 V or 4-20 mA output - 24 Vdc/Vac power supply (active 3-4 wire) - without display
Measuring range: -40 to +180 °C Power supply: 24 Vdc/Vac With display Probe: Stainless steel Probe length: 150 mm, fi 13 mm Mounting: Remote, 2 m cable 2 relay outputs
CP112-AO Differential Pressure Transmitter – Active Measuring range: -1,000 to +1,000 Pa (0–10 mbar) Protection: IP65 Power supply: 24 VAC/VDC – output 0–10 V or 4–20 mA 1-line display Measuring range settings: 100 Pa – 1.0 mbar 250 Pa – 2.5 mbar...
CP 113 Kimo Differential Pressure Sensor Measuring range: -10,000 to +10,000 Pa Active output: 0–10 V Display: 1-line Measuring range settings: 1,000 Pa – 10.0 mbar 2,500 Pa – 25.0 mbar 5,000 Pa – 50.0 mbar 7,500 Pa – 75.0 mbar 10,000 Pa – 100.0...
Display 4 digits Current 0–20 mA; Voltage 0–10 V and ±10 V (bipolar inputs supported) Voltage: 100 kΩ | Current: ≈ 50 Ω Sensor / loop supply 16 V, max 25 mA Power supply 10–40 Vdc; 19–28 Vac Power consumption Max 0.9 W Resolution 16 bit (up to...
4 digit loop powered display with 4-20 mA input signal Accuracy: 0,05% Max resolution: 16 bit Thermal drift: 0,005%/°K Analog input: Current 4-20 mA Power supply: By loop circuit (max 30 V) Max drop voltage: 7 V Programming: Front key menu,...
Passive current transducer 100 Adc for 4..20 mA current loop Input scales: Monopolar 0..10 A, 0..25 A, 0..50 A, 0..100 A; bipolar -10..0..+10 A, -25..0..+25 A, -10..0..+50 A, -25..0..+100 A Insulation: 1,5 kVdc on raw conductor Output/Power...
AC/DC contactless TRMS direct and alternate current (± 100 A) transducer, Hall Effect with 4..20 mA AO Power Supply: loop powered Accuracy Class: 0,5 Input Range: -100..+100 A ac/dc Measurement Type: TRMS Output Range: 4..20 mA Settings: Via DIP...
AC three phase network analyzer with energy meter Power Supply: 10-40 Vdc; 19-28 Vac Voltage Input: Up to 600 Vac Current Input: Up to 5 Arms Digital Output: Energy meter pulsea Analog Output: Re-transmitted (mA, V) Measured values: (Single or...
Power supply 10..40 Vdc; 19..28 Vac Power consumption Isolation 3.750 Vac (ingresso/uscita; ingresso/alimentazione) 1.500 Vac (uscita/alimentazione) Status LEd indicators power supply Response time Accuracy class 0,25% Thermal drift...
AC/DC voltage to DC current/voltage isolator/converter Voltage input: Up to 1000 VAC/DC Analog output: mA/V ModBus interface: RS485 - RS232 Insulation: 4.000 VAC Power Supply: 10-40Vdc / 19-28Vac Operating temperature: -20..65 ºC Accuracy class: 0,5
AC current to DC isolator / converter Input: current (0..5, 0..10 A) Output: current (0..20, 4..20 mA) Voltage (0..5, 0..10, 1..5, 2..10 V) Accuracy: 0,3% Power supply: 19..40 V DC, 19..28 V AC Max isolation: 3.750 VAC Tariff Number (TARIC):...
AC voltage to DC isolator / converter, 85-265 Vac/dc Power supply: 85..265 Vac/dc Input: Voltage, 41 scale pretarate 0..500 V Output: Current 0..20, 4..20 mA, voltage 0..5, 0..10, 1..5, 2..10 V Accuracy: 0,25% Max isolation: 4.000 V AC
AC current to DC isolator / converter Input: current (0..5, 0..10 A) Output: current (0..20, 4..20 mA) Voltage (0..5, 0..10, 1..5, 2..10 V) Accuracy: 0,3% Power supply: 85..265 V AC/DC Max isolation: 3.750 VAC Tariff Number (TARIC): 85437090...
AC/DC contactless TRMS direct and alternate current (± 300 A) transducer, Hall Effect with 4..20 mA AO Power Supply: loop powered Accuracy Class: 0,5 Input Range: -300..+300 A ac/dc Measurment Type: TRMS Output Range: 4..20 mA Settings: Via DIP...
This website uses cookies to provide a better user experience, analytics, advertising, and additional features. By selecting the option ‘I agree’, you allow the use of cookies for all the stated purposes. To adjust cookie permissions, click ‘Customize’. You can find more information about cookies
here.
These cookies are essential for the basic functioning of the website and are set in response to actions performed by the user, such as logging in, submitting forms, making purchases, and other interactions with website elements that go beyond simple passive browsing. These cookies are exempt from the requirement to obtain user consent.
Analytics cookies
Analytical cookies help us understand how users interact with the website, which enables us to improve the user experience. Data processing through these cookies is carried out on the basis of your explicit consent, which you can withdraw at any time.
Advertising cookies
These cookies are used to display personalized ads that are more relevant to you and your interests. They are also used to limit the number of times an ad is shown and to measure the effectiveness of advertising campaigns.
Social media cookies
These cookies enable the integration of social networks on our website, which includes sharing content or using social media features. The use of these cookies requires your consent, which we may obtain during your visit.