menu zapri
0,00 € 0

Sales program


Shown 468 - 504 from 1275 products
Code: 6B050002

SOFT STARTER, SSCe-034-V4-C1, 34A, 15 kW 400 VAC

LS Electric
SSC - LS Soft Starter Compact Series e - Without Motor Protection Normal duty: 15 kW 34A 400 VAC Heavy duty: 15 kW 30A 400 VAC Main voltage: 200 ~ 440 VAC Control Voltage: 110 ~ 240 VAC & 380 ~ 440 VAC Built-in bypass Without Motor Protection...
Out of stock
Code: 6B060005

SOFT STARTER, SSCi-060-V4-C1, 30 kW, 60A

LS Electric
Main voltage: 200 ~ 440 VAC Control Voltage: 110 ~ 240 VAC & 380 ~ 440 VAC Normal duty: 30 kW 60A 400 VAC Heavy duty: 22 kW 49A 400 VAC Built-in bypass With Motor Protection AC53b 4-6:594 Size: 98 x 201 x 165 mm (WxHxD) Weight: 2,1 kg IP20
In Stock (4)
Code: 119701052

GD350A-160G/185P-4 Frequency Inverter 160kW/185kW,400V, IP20, INVT

INVT
G- constant torque load P- special for fans and pums 160kW/305A Heavy Duty-150% Overload/1 min; 185kW/340A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
In Stock (1)
Code: 1323001100

LS Metasol Thermal Overload Relay MT-12/3K-7.5S, 6-9A, Tripping Class 10

LS Electric
LS Metasol Thermal Overload Relay MT-12/3K-7.5S, 6-9A, Tripping Class 10
Out of stock
Code: 590P-53372542-P00-U4V0

590P-53372542-P00-U4V0 590P-Series, 725A Four Quadrant Regenerative DC Drive

Parker
220-500VAC 3-Phase Input ; 725A Output Current Rating - Frame Size '4' 230V 1-Phase Auxiliary Supply Option Fitted Panel Mounted 6901 Keypad Option Fitted Armature Voltage feedback No Communications Option
Out of stock
Code: 6B060006

SOFT STARTER, SSCi-075-V4-C1, 37 kW, 75A

LS Electric
Main voltage: 200 ~ 440 VAC Control Voltage: 110 ~ 240 VAC & 380 ~ 440 VAC Normal duty: 37 kW 75A 400 VAC Heavy duty: 30 kW 65A 400 VAC Built-in bypass With Motor Protection AC53b 4-6:594 Size: 145 x 215 x 193 mm (WxHxD) Weight: 3,8 kg IP00
Out of stock
Code: 6B070001

SOFT STARTER, SSMe-0024B-V5-C1-H, 11 kW, 24A

LS Electric
Normal duty: 11 kW 24A 400 VAC Heavy duty: 7,5 kW 16A 400 VAC AC53b 3.0-10:350, Control Voltage: 110~120&220~240 VAC, Main Voltage: 200~525 VAC, Internal Bypass, No Motor protection IP20 Size: 152 x 336 x 231 mm (WxHxD) Weight: 4,8 kg
Out of stock
Code: 20G-44-0230-BF

20G-44-0230-BF Parker AC20 Series Frequency Inverter 11 kW 400 VAC

Parker
11 kW 23 A Heavy Duty-150% Overload/1 min Input: 380 ... 480 VAC ±10 % Three Phase Output: 380 ... 480 VAC ±10 % Three Phase V/f, sensorless vector control, torque control LED Keypad EMC FILTER-C3 50 °C operating temperature braking unit IP20,...
Out of stock
Code: 119701122

GD350A-185G/200P-4 Frequency Inverter 185kW/200kW,400V, IP20, INVT

INVT
G- constant torque load P- special for fans and pums 185kW/340A Heavy Duty-150% Overload/1 min; 200kW/380A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
Out of stock
Code: 1323001200

LS Metasol Thermal Overload Relay MT-12/3K-8.5S, 7-10A, Tripping Class 10

LS Electric
LS Metasol Thermal Overload Relay MT-12/3K-785S, 7-10A, Tripping Class 10
In Stock (9)
Code: 590P-53383042-P00-U4V0

590P-53383042-P00-U4V0 590P-Series, 830A Four Quadrant Regenerative DC Drive

Parker
220-500VAC 3-Phase Input ; 830A Output Current Rating - Frame Size '4' 230V 1-Phase Auxiliary Supply Option Fitted Panel Mounted 6901 Keypad Option Fitted Armature Voltage feedback No Communications Option
Out of stock
Code: 6B060007

SOFT STARTER, SSCi-085-V4-C1, 45 kW, 85A

LS Electric
Built-in bypass With Motor Protection Normal duty: 45 kW 85A 400 VAC Heavy duty: 37 kW 73A 400 VAC Main voltage: 200 ~ 440 VAC Control Voltage: 110 ~ 240 VAC & 380 ~ 440 VAC AC53b 4-6:594 Size: 145 x 215 x 193 mm (WxHxD) Weight: 3,8 kg IP00
Out of stock
Code: 119701123

GD350A-200G/220P-4 Frequency Inverter 200kW/220kW,400V, IP20, INVT

INVT
G- constant torque load P- special for fans and pums 200kW/380A Heavy Duty-150% Overload/1 min; 220kW/425A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
Out of stock
Code: 1323001300

LS Metasol Thermal Overload Relay MT-12/3K-11S, 9-13A, Tripping Class 10

LS Electric
LS Metasol Thermal Overload Relay MT-12/3K-11S, 9-13A, Tripping Class 10
Out of stock
Code: 590P-53412560-P00-U4V0

590P-53412560-P00-U4V0 590P-Series, 1250A Four Quadrant Regenerative DC Drive

Parker
220-500VAC 3-Phase Input ; 1250A Output Current Rating - Frame Size '6' Universal 115/230VAC 1-Phase Auxiliary Supply Panel Mounted 6901 Keypad Option Fitted Armature Voltage feedback No Communications Option
Out of stock
Code: 6B060008

SOFT STARTER, SSCi-100-V4-C1, 55 kW, 100A

LS Electric
Built-in bypass With Motor Protection Main voltage: 200 ~ 440 VAC Control Voltage: 110 ~ 240 VAC & 380 ~ 440 VAC Normal duty: 55 kW 100A 400 VAC Heavy duty: 45 kW 96A 400 VAC AC53b 4-6:594 Size: 145 x 215 x 193 mm (WxHxD) Weight: 3,8 kg IP00
Out of stock
Code: 6B070003

SOFT STARTER, SSMe-0052B-V5-C1-H, 22 kW, 52A

LS Electric
Normal duty: 22 kW 42A 400 VAC Heavy duty: 18,5 kW 35A 400 VAC AC53b 3.0-10:350, Control Voltage: 110~120&220~240 VAC, Main Voltage: 200~525 VAC, Internal Bypass, No Motor protection IP20 Size: 152 x 336 x 231 mm (WxHxD) Weight: 4,9 kg
Out of stock
Code: 119701124

GD350A-220G/250P-4 Frequency Inverter 220kW/250kW,400V, IP20, INVT

INVT
G- constant torque load P- special for fans and pums 220kW/425A Heavy Duty-150% Overload/1 min; 250kW/480A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
Out of stock
Code: 1323002700

LS Metasol Thermal Overload Relay MT-12/3K-15S, 12-18A, Tripping Class 10

LS Electric
LS Metasol Thermal Overload Relay MT-12/3K-15S, 12-18A, Tripping Class 10
Out of stock
Code: 590P-53416060-P00-U4V0

590P-53416060-P00-U4V0 590P-Series, 1600A Four Quadrant Regenerative DC Drive

Parker
220-500VAC 3-Phase Input ; 1600A Output Current Rating - Frame Size '6' Universal 115/230VAC 1-Phase Auxiliary Supply Panel Mounted 6901 Keypad Option Fitted Armature Voltage feedback No Communications Option
Out of stock
Code: 6B060009

SOFT STARTER, SSCi-140-V4-C1, 75 kW, 140A

LS Electric
Main voltage: 200 ~ 440 VAC Control Voltage: 110 ~ 240 VAC & 380 ~ 440 VAC Normal duty: 75 kW 140A 400 VAC Heavy duty: 55 kW 120A 400 VAC Built-in bypass With Motor Protection AC53b 4-6:594 Size: 200 x 240 x 215 mm (WxHxD) Weight: 6,1 kg IP00
Out of stock
Code: 6B070004

SOFT STARTER, SSMe-0064B-V5-C1-H, 30 kW, 64A

LS Electric
Normal duty: 30 kW 63A 400 VAC Heavy duty: 22 kW 51A 400 VAC AC53b 3.0-10:350, Control Voltage: 110~120&220~240 VAC, Main Voltage: 200~525 VAC, Internal Bypass, No Motor protection IP20 Size: 152 x 336 x 231 mm (WxHxD) Weight: 4,9 kg
Out of stock
Code: 119701125

GD350A-250G/280P-4 Frequency Inverter 250kW/280kW,400V, IP20, INVT

INVT
G- constant torque load P- special for fans and pums 250kW/480A Heavy Duty-150% Overload/1 min; 280kW/530A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
Out of stock
Code: 0705000541

MMS-32H Manual Motor Starter 1,0A; 0,63-1,0A , Icu= 100kA

LS Electric
MMS-32H Manual Motor Starter 1,0A; 0,63-1,0A , Icu= 100kA
In Stock (10+)
Code: 1271004100

GTK-12M LS Metasol Thermal Overload Relay 11A (9 - 13A)

LS Electric
LS Metasol Thermal Overload Relay GTK-12M 11A (9 - 13A) for GMC/GMD
Out of stock
Code: 590P-53419560-P00-U4V0

590P-53419560-P00-U4V0 590P-Series, 1950A Four Quadrant Regenerative DC Drive

Parker
220-500VAC 3-Phase Input ; 1950A Output Current Rating - Frame Size '6' Universal 115/230VAC 1-Phase Auxiliary Supply Panel Mounted 6901 Keypad Option Fitted Armature Voltage feedback No Communications Option
Out of stock
Code: 6B060010

SOFT STARTER, SSCi-170-V4-C1, 90 kW, 170A

LS Electric
Main voltage: 200 ~ 440 VAC Control Voltage: 110 ~ 240 VAC & 380 ~ 440 VAC Normal duty: 90 kW 170A 400 VAC Heavy duty: 75 kW 142A 400 VAC Built-in bypass With Motor Protection AC53b 4-6:594 Size: 200 x 240 x 215 mm (WxHxD) Weight: 6,1 kg IP00
Out of stock
Code: 6B070005

SOFT STARTER, SSMe-0069B-V5-C1-H, 37 kW, 69A

LS Electric
Normal duty: 37 kW 69A 400 VAC Heavy duty: 30 kW 62A 400 VAC AC53b 3.0-10:350, Control Voltage: 110~120&220~240 VAC, Main Voltage: 200~525 VAC, Internal Bypass, No Motor protection IP20 Size: 152 x 336 x 231 mm (WxHxD) Weight: 4,9 kg
Out of stock
Code: 15G-11-0025-BF

15G-11-0025-BF Parker AC15 Series Frequency Inverter 0,37 kW 230 VAC

Parker
0,37 kW 2,5 A Heavy Duty-150% Overload/1 min Input: 220-240 VAC ±10 % , 1 Phase Output: 220 ... 240 VAC ±10 % Three Phase V/f, sensorless vector control, torque control LED Keypad EMC FILTER-C3 50 °C operating temperature braking unit IP20,...
Out of stock
Code: 119701141

GD350A-090G/110P-4 Frequency Inverter 90kW/110kW, 400V, IP20, INVT

INVT
G- constant torque load P- special for fans and pums 90kW/180A Heavy Duty-150% Overload/1 min; 110kW/215A Normal Duty-110% Overload/1 min; 3 Phase Input,3 Phase Output, 380-480 Volts control modes: U/f, IM motor , PM motor Output frequency:...
Out of stock
Code: 0705000641

MMS-32H Manual Motor Starter 1,6A; 1,0-1,6A, Icu= 100kA

LS Electric
MMS-32H Manual Motor Starter 1,6A; 1,0-1,6A, Icu= 100kA, High breaking
In Stock (10+)
Code: 1271003100

GTK-12M LS Metasol Thermal Overload Relay 0.33A (0.25 - 0.4A)

LS Electric
LS Metasol Thermal Overload Relay GTK-12M 0.33A (0.25 - 0.4A) for GMC/GMD
Out of stock
Code: 590PXD-0011-UK-0

590PXD/0011/UK/0 Parker Control Door with 6901 Keypad

Parker
Includes: Control board AH50075U002 Adaptor pcb AH466405U001 6901 keypad Fitted to 591PX and 590PX - frame size 1,2 3,6 & size H - also used on external stack 598P and 599P DC thyristor drives
Out of stock
Code: 6B060011

SOFT STARTER, SSCi-200-V4-C1, 110 kW, 200A

LS Electric
Main voltage: 200 ~ 440 VAC Control Voltage: 110 ~ 240 VAC & 380 ~ 440 VAC Normal duty: 110 kW 200A 400 VAC Heavy duty: 90 kW 165A 400 VAC Built-in bypass With Motor Protection AC53b 4-6:594 Size: 200 x 240 x 215 mm (WxHxD) Weight: 6,1 kg IP00
Out of stock
Code: 6B070006

SOFT STARTER ,SSMe-0105B-V5-C1-H, 45 kW, 105A

LS Electric
Normal duty: 45 kW 86A 400 VAC Heavy duty: 37 kW 69A 400 VAC AC53b 3.0-10:350, Control Voltage: 110~120&220~240 VAC, Main Voltage: 200~525 VAC, Internal Bypass, No Motor protection IP20 Size: 152 x 336 x 231 mm (WxHxD) Weight: 5,5 kg
Out of stock
Code: 15G-11-0045-BF

15G-11-0045-BF Parker AC15 Series Frequency Inverter 0,75 kW 230 VAC

Parker
0,75 kW 4,5 A Heavy Duty-150% Overload/1 min Input: 220-240 VAC ±10 % , 1 Phase Output: 220 ... 240 VAC ±10 % Three Phase V/f, sensorless vector control, torque control LED Keypad EMC FILTER-C3 50 °C operating temperature braking unit IP20,...
Out of stock